Strany 1 - Installation Guide

Custom PanelBuilt-in Bottom-Freezer RefrigeratorInstallation Guide

Strany 2 - Table of Contents

Custom Grille Dimensions (Bottom-Freezer)10Reverse dimensions for other end.1/2”(1.27 cm)1-1/2”(3.81 cm)1/4” Radius(.64 cm)2-3/4”(6.98 cm)1/2”(1.27 cm

Strany 3 - Please Read and Follow

3 25/32”(9.60 cm)27/32”(.84 cm)9/16”(1.42 cm)1/4”(.635 cm)16.5˚20.0˚Note: This part should be located at the center of the grille. If desired, two per

Strany 4 - Please Read and Follow!

12Top ViewTop ViewDoor24”(61.0 cm)standard cabinet depth25”(63.5 cm)countertopdepth25”(63.5 cm)countertopdepth25”(63.5 cm)countertopdepthWall3/4”(1.9

Strany 5 - Dimensions (Bottom-Freezer)

133/4”(1.9 cm)End panel1”(2.5 cm)1/4”(0.6 cm)Z-Bracket21-3/4”(55.2 cm)21-3/4”(55.2 cm)24”(61.0 cm)Optional kickplate notch(Dimensions determined by ca

Strany 6 - 36” Bottom-Freezer

14Custom Panel General InformationCustom finishing options• All installations must allow for the refrigeratorand freezer door to open a minimum of 90˚

Strany 7

157Slide custom wood panel to the hinge side, ensuring “Z” bracket engages the door bracket.8x13x2x2Reinstall handle side door trim and door trim scre

Strany 8 - Anti-Tip Dimensions

16Open freezer door. Remove door trim screws and door trim with a phillips screwdriver.Remove bracket.1x162Attach bracket to the custom panel. Align a

Strany 9 - 36” Custom Panels

17Install Door Trim InsertUse the roll of trim insert located in the drawer insidethe unit to apply to the door trim.1Measure and cut 2-1/16” (5.2 cm

Strany 10 - 36” Custom Grille

1812Remove air grille center blade.Remove two 1/4” (0.6 cm) screws with a magneticextended screwdriver at least 8” (20.3 cm) long.34Pull air grille as

Strany 11 - Dual 36” Custom Grille

196Insert custom air grille assembly.Install two 1/4” (0.6 cm) screws with a magneticextended screwdriver at least 8” (20.3 cm) long.Install custom ai

Strany 12 - Cabinet Information

2Table of ContentsWarnings & Important Information ____________________________________________________________________3Dimensions and Specificati

Strany 13 - Custom Side Panel Dimensions

20General InformationArea RequirementsVerify the following:• Unit can fit into residence and can be movedaround corners and through doorways.• Floors

Strany 14

21General Information• DO NOT use the self-piercing feature of a saddlevalve. The hole made by the piercing lance is toosmall for the water flow rate

Strany 15

2212Place unit in front of cutout.Pull the center grille louver up at an angle and pull out.34Using an 8” (20.3 cm) magnetic nut driver, remove the tw

Strany 16 - (Bottom-Freezer cont.)

23Remove four side screws and remove unit top.Loosen the four hinge screws. Adjust door. Retighten four hinge screws.Replace unit top and four side sc

Strany 17 - (if required)

243”3”3”10aPlace unit within 3” of being flush with cabinets. Note: To avoidcabinet damage, place cardboard between cabinets and unit. Whenmoving unit

Strany 18 - Custom Grille Installation

25Lift unit off rollers to desired height and level unit using a 5/16” head wrench.Note: DO NOT use an electric device. Overtightening can cause damag

Strany 19

26Align holes on both ends of louvered panels and insert screws.Using a phillips screwdriver, attach the kickplate to the unit and adjust to desired h

Strany 20 - General Information

27Water Filter System Specification and PerformanceData SheetThis system has been tested according to NSF/ANSI 42/53 for reduction of the substances l

Strany 21

28Replace top air grille.Using an 8” magnetic nut driver, replace the two 1/4” screws.Replace the center grille louver.Open door. The display should f

Strany 22 - Installation

29Performance Checklist□ Verify cabinet size.□ Verify electrical supply and water supply (if applicable).□ Install anti-tip device(s) and verify unit

Strany 23 - Front of unit

3IMPORTANT – Please Read and Follow• Make sure that incoming voltage is the same asunit rating. An electric rating plate specifyingvoltage, frequency,

Strany 24 - Installation (cont.)

30Verify OperationsControl Panels1. Press “Activate Controls” pad.2. Verify unit is not in Sabbath Mode.If in Sabbath Mode:A. The Sabbath Mode will di

Strany 25 - Hinge Adjustment (cont.)

31If service is required, call your dealer or authorized service agency. The name of the authorizedservice agency can be obtained from the dealer or d

Strany 26 - (Bottom-Freezer)

Viking Range, LLC111 Front StreetGreenwood, Mississippi 38930 USA(662) 455-1200For product information,call 1-888-(845-4641)or visit our web site at b

Strany 27 - Data Sheet

IMPORTANT–Please Read and Follow!4A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/locallaws, or local ordinances.•

Strany 28 - Final Installation

Dimensions (Bottom-Freezer)536” Bottom-Freezer51-7/8”(131.8 cm)23-1/16”(58.6 cm)3-19/32”(9.1 cm)82-3/4”(210.2 cm)min.to84-1/16”(213.5 cm)max.Measureme

Strany 29 - Performance Checklist

Specifications (Bottom-Freezer)636” Bottom-FreezerDescription FDBB/CFDBBOverall width 36” (91.5 cm)Overall height (from bottom) 82-3/4” (210.2 cm) min

Strany 30 - Verify Operations

79”(22.9 cm)73-3/8”(186.4 cm)82-7/8”(210.5 cm) min.anti-tip board &opening height84-1/16”(213.5 cm) max.anti-tip board &opening height36”(91.5

Strany 31 - Service & Registration

8Anti-Tip Dimensions (Bottom-Freezer)One 2”x 4” mounting board1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)Note: If unit is installed deeper than 24” (61.0 cm), t

Strany 32 - (100115)

35-1/4”(89.5 cm)23-1/16”(58.6 cm)3/4”(1.9 cm)35-1/4”(89.5 cm)32-1/4” to notch(81.9 cm)5/8”(1.6 cm)51-7/8”(131.8 cm)51-1/4”(130.2 cm)3/4”(1.9 cm)Note: